POWER MEASUREMENT

The 3 factors to take a decision

 

 

 

Factor  1 :

 

Choice of Central Source Luminaires (CSL)

 

Ask your supplier abour their energy consumption.

 

 

 

Factor  2 :

 

Calculation of the power of a DC or AC energy sources

 

The power and voltage are defined by the specifications; then follow the methods below :

 

DC energy

 

Evacuation unit example consumption 3.6W = 25 Luminaires

Ambien unit = consuming 11W = 15

 

Evacuation : 25 x 3.6 W = 90 W + Ambient : 15 x 11 W = 165 W = Total power : 255 W

 

 

AC energy

 

Evacuation unit = 15 luminaires

 

Ambient = consuming 30 VA = 12 luminaires

 

Evacuation : 15 x 3 VA = 45 VA + Ambient : 12 x 30 VA = 360 VA = Total power : 405 VA

 

 

 

 

Paramètre 3 :

 

Definition of a Energy source. After calculating the power of the central source, APS France offers two ranges of products depending on the voltage of use

 

 

DC Energy

 

Recommended power :

 

Recommended margin 20% -> 255 + 20% = 306 W,  SEC 48/360W

 

 

AC Energy

 

Recommended power :

 

Recommended margin 20 % -> 405 + 20 % = 486 VA, soit une SEA 600 VA

 

FR

BRIGHT THEME

CONTACT US